Free sampling tool

AQL Calculator: ISO 2859-1 and ISO 2859-2

Sample size and accept / reject numbers for apparel and home-textile lots. Use ISO 2859-1 for a continuing series of lots with switching rules, or ISO 2859-2 for an isolated, one-off lot.

Inspection severity

Standard plan for a factory in a continuing series.

Code letter K · Normal · Level II
Sample size
125
Major 2.5 Ac / Re
7 / 8
Minor 4.0 Ac / Re
10 / 11

Inspect 125 pieces. Accept the lot when major defects are at most 7 and minor defects at most 10. Reject at 8 major or 11 minor.

ISO 2859-1 switching rules, step by step

ISO 2859-1 only gives the protection its AQL implies when the switching rules are applied across a series of lots from the same factory. Staying on Normal forever means a drifting factory is never pushed onto a stricter plan.

ClauseFrom → ToTriggerWhat it means
9.3.1Normal → Tightened2 of the last 5 lots rejectedSame sample size, fewer defects allowed. Takes priority over everything else.
9.3.2Tightened → Normal5 consecutive lots acceptedClears the tightened run and resets the counters.
9.3.4Tightened → DiscontinueTightened not cleared within 5 lotsStop accepting lots from this factory until quality improves. Escalate to QA management and the buyer.
9.3.3Normal → ReducedSwitching score reaches 30 and production is marked steadyAccepted lots score +3 when the lot would also pass at the next tighter AQL, or +2 when Ac ≤ 1. Any rejected lot resets the score to 0.
9.3.5Reduced → NormalA rejected lot, or production no longer steadyReduced uses the smaller Table 2-C sample, so it reverts on the first sign of drift. In ISO 2859-1:1999 there is no "ambiguous zone" — Re is always Ac + 1, so a lot is either accepted or rejected.

Try the switching rules on a series of lots

Current severityNormalSwitching score 0 / 30

Model assumes Ac ≥ 2 and that accepted lots would also pass one AQL step tighter (+3 score).

ISO 2859-2: protecting the buyer on an isolated lot

A one-off order, a trial run, a sample shipment or a new factory has no series for switching rules to act on. ISO 2859-2 Procedure A is built for exactly that case. You choose a limiting quality (LQ): a defect rate you consider clearly unacceptable. The plan is designed so a lot at that LQ is accepted no more than about 10 % of the time.

That is the key difference. ISO 2859-1 protects the producer across a series: a lot at the AQL is accepted most of the time, and the switching rules supply the buyer's protection over time. ISO 2859-2 protects the consumer on a single lot. An LQ value is not an AQL value; an LQ of 2 % and an AQL of 2.5 describe very different plans.

Choose a lower LQ for safety-critical or brand-critical defects, such as needle contamination, choking hazards or mislabelled fibre content, and a higher LQ for cosmetic issues. Small lots at a strict LQ often require inspecting every piece.

Frequently asked questions

What are the ISO 2859-1 switching rules?
Inspection starts on Normal. Two rejected lots out of five consecutive lots moves to Tightened. Five consecutive accepted lots on Tightened returns to Normal. If Tightened is not cleared within five lots, acceptance is discontinued until quality improves. Reduced inspection may be permitted by the responsible authority once the switching score reaches 30 and production is steady; any rejected lot returns inspection to Normal.
When should I use ISO 2859-2 instead of ISO 2859-1?
Use ISO 2859-2 for an isolated lot, such as a one-off order, a trial run or a new factory with no history. ISO 2859-1 is designed for a continuing series of lots where the switching rules can act. Without that series, an AQL plan gives the buyer less protection than the AQL figure suggests.
Is an LQ the same as an AQL?
No. An AQL is a quality level that a plan accepts most of the time across a series. A limiting quality (LQ) is a poor quality level that an ISO 2859-2 plan accepts no more than about 10% of the time. An LQ value should never be read as an AQL value.
Does Reduced inspection happen automatically?
No. Reduced inspection is permitted, not earned automatically. It needs a switching score of at least 30, steady production and approval from the responsible authority. In QualityIris the severity is an advisory recommendation that the inspector can override with a written reason.

Run these plans inside every Final Audit